Knowledge base

Heat exchanger scaling: how scale forms and affects performance

Scaling occurs when dissolved minerals precipitate from a fluid and form deposits on the heat-transfer surfaces of a heat exchanger. As this layer develops, it adds thermal resistance between the fluid and the metal surface. Further build-up can also restrict flow channels and affect the hydraulic performance of the heat exchanger.

Calcium carbonate is one of the most familiar forms of scale, but heat exchanger scaling is not limited to limescale. Depending on the water chemistry and process conditions, deposits may also contain calcium sulphate, magnesium compounds, silica or other sparingly soluble minerals.

The composition, location and thickness of these deposits ultimately determine how strongly scaling affects heat exchanger performance.

Scaling in a heat exchanger

Scaling is a specific form of fouling caused by dissolved salts or minerals precipitating from the process fluid and forming a solid layer on plates, tubes or other heat-transfer surfaces.

Common scale-forming compounds can include:

  • Calcium carbonate
  • Calcium sulphate
  • Magnesium compounds
  • Silica and silicates
  • Other mineral deposits depending on the water or process fluid

The terms scaling and limescale are therefore not completely interchangeable. Limescale generally refers to calcium-based deposits, whereas scaling is the broader technical term for mineral precipitation and deposition.

Scale usually develops gradually. A heat exchanger can therefore continue operating while thermal resistance is already increasing on the heat-transfer surface.

How scale forms in a heat exchanger

Scale begins to form when conditions within the fluid change to the point where certain dissolved substances can no longer remain fully in solution. Once the fluid becomes saturated or supersaturated with a scale-forming compound, crystals can begin to form and attach to heat-transfer surfaces.

Changes in temperature, pH, pressure and concentration can all influence the solubility of salts and therefore the tendency for scaling to occur.

Dissolved minerals and saturation

Water naturally contains dissolved minerals. Their concentration depends on the water source, treatment method and process in which the water is used.

As long as these minerals remain below their solubility limit under the prevailing conditions, they remain dissolved. Once that limit is exceeded, the solution becomes supersaturated and precipitation can begin.

The first crystals can form directly on a heat-transfer surface or elsewhere in the fluid before attaching to that surface. Existing deposits can then provide additional nucleation sites, allowing the scale layer to continue growing.

For calcium carbonate, factors such as calcium concentration, alkalinity, pH and temperature all affect scaling tendency. Other minerals have their own solubility behaviour.

The influence of temperature

Temperature is particularly important because the solubility of different salts changes as temperature changes.

For compounds such as calcium carbonate, increasing temperature can increase the tendency to precipitate. This means that local conditions at a hot heat-transfer surface can differ significantly from those in the bulk fluid.

The result is that scaling may develop more strongly in certain areas of the exchanger than in others.

A plate pack or tube bundle can therefore show substantial differences in deposit thickness even though the same fluid passes through the entire heat exchanger. Local wall temperature, flow distribution and fluid concentration all contribute to these differences.

Water chemistry, pH and flow conditions

Scale formation is rarely controlled by one parameter alone. It usually results from a combination of water chemistry and operating conditions.

Relevant factors include:

  • Mineral concentration
  • pH
  • Fluid and surface temperature
  • Concentration of dissolved solids
  • Residence time
  • Flow velocity
  • Evaporation or concentration effects
  • Water treatment
  • Surface properties and condition

Flow conditions are also relevant. Higher velocity and turbulence can increase wall shear stress and make it more difficult for deposits to attach or remain on the surface. Lower-velocity areas are generally more susceptible to accumulation. This does not mean that increasing flow will automatically prevent scaling, as the chemistry of the fluid and the operating conditions remain decisive.

Scaling as a specific form of heat exchanger fouling

Fouling is the general term for unwanted material accumulating on heat-transfer surfaces. Scaling is one form of fouling, but not every fouled heat exchanger is affected by mineral scale.

Several fouling mechanisms can occur:

  • Scaling: precipitation and deposition of dissolved mineral compounds.
  • Particulate fouling: accumulation of suspended solids, sediment or sludge.
  • Biofouling: accumulation and growth of microorganisms and biological material.
  • Corrosion fouling: corrosion products forming on the surface or entering the exchanger from elsewhere in the system.
  • Process fouling: deposits such as oils, fats or other product residues.

More than one type of fouling may be present at the same time. Mineral deposits can, for example, create a rougher surface on which other contaminants accumulate more easily.

This distinction matters when selecting the correct method for heat exchanger cleaning. The type and composition of the deposit are at least as important as the visible amount of contamination.

The effect of scaling on heat exchanger performance

Scaling initially affects heat transfer by adding thermal resistance. As deposits become thicker and start to restrict flow passages, hydraulic performance can also deteriorate.

This means that thermal and hydraulic performance do not necessarily decline at the same rate.

Reduced heat transfer

Efficient heat transfer requires energy to pass from one fluid through the plate or tube wall to the second fluid.

A layer of scale adds another material between the fluid and that metal surface:

Scale deposit → additional thermal resistance → lower overall heat-transfer coefficient → reduced heat transfer under comparable operating conditions.

The overall heat-transfer coefficient, often expressed as the U-value, accounts for the different resistances between the two fluids. Fouling resistance is one of these components. Alfa Laval similarly includes a specific fouling resistance factor in calculations of the overall heat-transfer coefficient.

Because many mineral deposits conduct heat considerably less effectively than the exchanger material itself, even a relatively thin deposit can affect thermal performance.

Within the installation, this may become visible through changing outlet temperatures, reduced cooling or heating capacity or an increasing approach temperature.

Increasing pressure drop and changing flow

Scaling does not necessarily cause a significant increase in pressure drop immediately.

A thin deposit may already reduce heat transfer while leaving most of the flow area available. As scaling continues to build, however, the effective diameter of tubes or the free space between plates becomes smaller.

The hydraulic resistance then increases.

Possible effects include:

  • Increasing pressure drop across the heat exchanger
  • Reduced flow at the same pumping conditions
  • Additional pump power required to maintain flow
  • Uneven distribution between channels
  • Local low-velocity areas that can encourage further fouling

This distinction is important when analysing exchanger performance. A relatively stable differential pressure does not prove that the heat-transfer surfaces are clean. Blue Orange’s existing knowledge article on high pressure drop across a heat exchanger also highlights that thermal performance can deteriorate without a simultaneous major increase in pressure drop.

Increased energy demand and reduced process capacity

As thermal performance declines, the surrounding process may need to compensate.

Depending on the installation, this can result in:

  • Additional pumping power
  • Increased heating or cooling demand
  • Longer process times
  • Higher utility consumption
  • Reduced production capacity
  • Inability to achieve the required outlet temperature

Fouling can therefore develop from a maintenance issue into an operational and energy-efficiency issue. Increasing fouling has been associated with both higher energy requirements and higher pressure losses in industrial heat exchanger systems.

Recognising scaling in operating data

Scale generally builds gradually, which makes trend data more valuable than a single measurement.

Possible indicators include:

  • Changing inlet and outlet temperatures
  • Declining heating or cooling capacity
  • Increasing approach temperature
  • Rising pressure drop
  • Changing flow rates
  • Increasing energy consumption
  • Longer heating or cooling cycles
  • Operation progressively moving away from its original performance conditions

The development of these values over time is particularly relevant. A gradual change under otherwise comparable operating conditions can indicate increasing thermal or hydraulic resistance.

These symptoms should not be treated as proof of scaling. Reduced performance may also be caused by other fouling mechanisms, changes in flow, altered fluid properties, incorrect controls or problems elsewhere in the installation.

For that reason, process data and physical inspection provide a more reliable assessment when used together.

The same approach is relevant when determining the right time for heat exchanger maintenance. Performance trends are generally more informative than relying solely on a fixed maintenance interval.

Scaling in plate heat exchangers

Plate heat exchangers use relatively narrow flow channels between individual heat-transfer plates. Deposits that reduce this available channel space can therefore have a relatively large hydraulic effect as they continue to accumulate.

This does not mean that plate heat exchangers and other heat exchanger types automatically develop scale faster.

The corrugated plate geometry in a plate heat exchanger typically produces considerable turbulence and wall shear stress. Under suitable operating conditions, this can help reduce the tendency for material to accumulate.

The narrow channels do, however, make the relationship between deposit thickness and available flow area particularly important. A deposit that represents only a small restriction in a large pipe may occupy a much more significant proportion of a narrow plate channel.

Scaling can also occur in shell-and-tube heat exchangers. Deposits may develop on either the tube side or shell side depending on the process fluids and operating conditions.

In tubes, scale adds thermal resistance and can gradually reduce the effective internal diameter. On external tube surfaces, deposits can similarly reduce heat transfer even without restricting the inside of the tube.

The heat exchanger construction therefore influences where scaling develops and how its effects become visible, rather than changing the fundamental mechanism behind scale formation.

Determining whether scaling is responsible for performance loss

A useful assessment begins with the operating history rather than with the visible deposit alone.

Historical process data can reveal when performance started to change and whether thermal and hydraulic deviations developed at the same time.

Relevant data includes:

  • Inlet and outlet temperatures
  • Flow rates
  • Inlet and outlet pressures
  • Differential pressure
  • Process load
  • Energy consumption
  • Previous cleaning intervals
  • Earlier inspections and overhaul reports

Keeping this information throughout the service life of an exchanger makes it easier to distinguish gradual deterioration from normal process variation. Blue Orange provides further guidance on the information worth keeping throughout a heat exchanger’s service life.

After opening or dismantling the unit, physical inspection provides additional information about the nature, location and distribution of deposits.

The amount of visible material alone does not determine the effect on performance.

A relatively thin, insulating layer covering a large proportion of the active heat-transfer area can have more thermal impact than a much thicker local deposit in a less critical location.

Deposit distribution can also provide clues about its cause. Concentrated scaling in particular sections of a plate pack or tube bundle may be linked to local temperature differences, poor distribution or low-flow zones.

As part of heat exchanger maintenance and repair, contamination, condition, flow, leakage and technical performance can therefore be assessed together rather than as separate issues.

The deposit determines the appropriate cleaning method

A hard deposit does not automatically indicate one specific cleaning process.

The appropriate method depends on several factors:

  • Chemical composition of the deposit
  • Thickness
  • Hardness and adhesion
  • Plate or tube material
  • Gasket compatibility
  • Heat exchanger construction
  • Process fluid
  • Accessibility of the contaminated surfaces
  • Overall technical condition

Mineral scale can often be addressed with chemical cleaning because suitable cleaning solutions can dissolve specific mineral compounds. The correct chemistry, concentration, temperature and exposure time depend on both the deposit and the materials of construction.

Other forms of contamination may be better suited to ultrasonic, high-pressure or mechanical cleaning.

Blue Orange therefore starts heat exchanger cleaning with an assessment of the fouling and exchanger construction. Its cleaning services specifically include chemical cleaning for scale, lime, sludge and other water-side deposits.

Cleaning alone may not always be sufficient. If dismantling reveals damaged plates, deteriorated gaskets, corrosion or other defects, a complete heat exchanger overhaul can combine cleaning with inspection, component replacement, repair, reassembly and testing.

Reducing the development of scale

Scaling cannot be completely eliminated in every process, but the rate of formation can often be influenced by controlling the conditions that promote precipitation and deposition.

Relevant measures can include:

  • Appropriate water treatment
  • Monitoring mineral concentration and water quality
  • Controlling pH where technically applicable
  • Avoiding unnecessarily high surface temperatures
  • Maintaining suitable flow conditions
  • Preventing prolonged operation at very low flow
  • Monitoring thermal performance and pressure drop
  • Cleaning before deposits become excessively established

The appropriate measures depend on the application.

A closed cooling-water system, seawater circuit, evaporative process and once-through water system all operate under different chemical and hydraulic conditions.

Recurring scaling should therefore not be viewed solely as a cleaning problem. It can also provide information about the operating conditions of the system.

Changes in production, flow, temperature or water treatment may alter the scaling tendency even when the heat exchanger itself has not changed. Alfa Laval has documented industrial cases in which changed operating conditions and reduced flow contributed to increased fouling in previously well-performing heat exchangers.

Scaling as part of a condition-based maintenance strategy

Scaling becomes particularly disruptive when it is only detected after a heat exchanger can no longer achieve its required duty.

Monitoring temperatures, flow and pressure drop over time makes gradual changes easier to identify. This allows maintenance decisions to be based more closely on the actual condition and performance of the exchanger.

After cleaning or heat exchanger overhaul, the restored operating data can also provide a useful new performance baseline. Future measurements can then be compared against that reference.

This approach makes it easier to distinguish normal operating variation from gradual deterioration and helps determine when inspection or cleaning becomes technically relevant.

Targeted maintenance starts with the correct diagnosis

Scaling usually develops through a combination of water chemistry, temperature, flow and operating conditions. By identifying changes in heat transfer, flow and pressure drop and establishing the nature of the deposits, the required maintenance can be selected more accurately.

Blue Orange supports the inspection, cleaning, testing, maintenance and overhaul of heat exchangers, with the work based on the actual condition of the unit. When scaling, fouling or declining performance starts affecting an installation, contact us to assess the cause and determine the most appropriate next step.

Scaling is the formation of mineral deposits when dissolved compounds precipitate from a fluid and accumulate on heat-transfer surfaces. Calcium carbonate is a common example, although scale can also consist of sulphates, magnesium compounds, silica and other mineral deposits.

A scale layer adds thermal resistance between the process fluid and the heat-transfer surface. This lowers the overall heat-transfer coefficient and can reduce the heating or cooling capacity of the exchanger.

Possible indicators include changing outlet temperatures, reduced heating or cooling capacity, an increasing approach temperature, rising pressure drop, reduced flow and higher energy consumption. These symptoms can have other causes, so operating data should be combined with inspection before scaling is confirmed.

 

Scaling cannot always be prevented completely. Appropriate water treatment, controlled operating conditions, adequate flow, performance monitoring and timely cleaning can reduce the rate at which deposits develop.

Scale forms when operating conditions cause dissolved minerals to exceed their solubility limit. Temperature, pH, concentration, water chemistry and local surface conditions can all contribute to precipitation and subsequent deposit growth.

Yes. As scale deposits grow, they can narrow tubes or plate channels and increase hydraulic resistance. Thermal performance can, however, deteriorate before a significant increase in pressure drop becomes visible.

The appropriate method depends on the chemical composition and condition of the deposits and on the exchanger materials. Chemical cleaning is often suitable for mineral scaling, while other types of fouling may require ultrasonic, high-pressure or mechanical cleaning.