A rising pressure drop, declining cooling capacity or changing outlet temperature can indicate fouling inside a heat exchanger. However, these symptoms do not automatically determine how the heat exchanger should be cleaned.
Mineral scale requires a different approach from oil, sludge or biological fouling. Even the same type of contamination can require a different cleaning method in two different heat exchangers. Design, material, accessibility of the fouled surface and the technical condition of the heat exchanger all influence the decision.
A suitable cleaning approach therefore starts by identifying the type and location of the contamination and the material on which it has formed. From there, the most appropriate cleaning method can be selected.
Which cleaning method suits which type of fouling?
In general, chemical cleaning is considered when deposits can be dissolved or loosened with a cleaning solution that is compatible with the materials of the heat exchanger. Ultrasonic cleaning is particularly useful for complex geometries and difficult-to-reach surfaces, where cavitation can remove contamination from small passages, between fins or from other inaccessible areas. High-pressure cleaning removes deposits mechanically using water and can be effective for stubborn contamination on surfaces that are accessible and able to withstand the mechanical load.
These are not fixed rules. The correct method depends on the combination of fouling, heat exchanger design, material, accessibility and technical condition.
Method | Particularly suitable for | Typical contamination | Typical applications | Main advantage | Key consideration |
Deposits that can be chemically dissolved or loosened | Scale, mineral deposits, corrosion products, certain oil or organic residues | Plate heat exchangers, shell & tube units, condensers, evaporators | Can reach internal surfaces without direct mechanical access | Chemistry must be compatible with the contamination, material, gaskets and seals | |
Complex and difficult-to-reach geometries | Sludge, salt, fine deposits, oils and certain types of biofouling | Charge air coolers, oil coolers, air coolers and marine coolers | Reaches narrow passages, fins and complex surfaces | Component must be suitable for treatment in an ultrasonic bath | |
Mechanically removable deposits on accessible surfaces | Sludge, hard deposits, scale and strongly adhering contamination | Tubes, tube bundles and certain industrial heat exchangers | Strong mechanical cleaning action without cleaning chemicals | Pressure, nozzle, distance and material condition must be properly controlled |
The type of fouling is therefore an important starting point, but it is not the only selection criterion.
When should you choose chemical cleaning for a heat exchanger?
During chemical cleaning, a cleaning solution is used to dissolve, soften or release deposits from the heat-transfer surfaces. The appropriate chemistry depends on both the contamination and the materials with which the cleaning solution comes into contact.
Mineral scale, for example, requires a different treatment from oil, grease or organic contamination. Concentration, temperature, circulation and contact time can also influence the cleaning result.
This can make chemical cleaning particularly useful when direct mechanical access is limited but the contamination can still be reached and removed chemically.
Chemical cleaning without complete disassembly
For certain heat exchangers, chemical cleaning can be performed as Cleaning in Place, or CIP. A cleaning solution is circulated through the heat exchanger without fully dismantling the unit.
This may be suitable when:
- The internal passages can still be circulated effectively
- The cleaning solution can reach the contaminated surfaces
- The deposits are chemically removable
- The materials, gaskets and seals are compatible with the selected chemistry
In these situations, CIP can avoid unnecessary disassembly.
That does not mean chemical cleaning can always be performed without opening the heat exchanger. Heavily restricted passages, mixed contamination or the need to inspect plates, tubes or gaskets may still make disassembly necessary.
Material compatibility defines the limits
When selecting a chemical cleaning process, it is important to consider not only what the cleaning solution removes, but also how it affects the heat exchanger itself.
Stainless steel, titanium, aluminium and copper alloys do not respond in the same way to every chemical environment. Gaskets, bonded components and coatings may introduce additional limitations.
A more aggressive cleaning solution is therefore not automatically a more effective solution. The objective is to remove the deposits while remaining within the material and design limitations of the heat exchanger.
When should you choose ultrasonic cleaning?
Ultrasonic cleaning uses a different mechanism. The component is submerged in a liquid bath in which high-frequency sound waves are generated.
These sound waves create microscopic cavitation bubbles. As the bubbles collapse, they produce localised cleaning forces that help release contamination from the surface.
The main advantage is accessibility.
Where brushes, water jets or other mechanical methods cannot easily reach, the cleaning fluid in an ultrasonic bath can penetrate small passages and complex geometries. This makes ultrasonic cleaning particularly useful for heat exchangers with:
- Fine fins
- Narrow passages
- Complex geometries
- Large numbers of difficult-to-access surfaces
At Blue Orange, this method is used for equipment including charge air coolers, oil coolers, air coolers and marine coolers.
Why ultrasonic cleaning is not automatically the best option
Difficult accessibility alone does not make ultrasonic cleaning the correct method.
The type and thickness of the deposits still matter. Heavy mineral scale may respond better to chemical treatment, while thick mechanically removable deposits can require another cleaning process.
The component must also be suitable for treatment in a controlled ultrasonic bath.
Ultrasonic cleaning is therefore particularly valuable when complex geometry and accessibility are a significant part of the cleaning challenge.
When should you choose high-pressure cleaning?
High-pressure cleaning, sometimes referred to as hydrojetting, is a mechanical cleaning method. A controlled water jet is used to physically remove contamination from the heat-transfer surface.
This method can be suitable when the contamination:
- Is hard or strongly adhered
- Does not need to be dissolved chemically
- Is mechanically accessible
- Can be removed without damaging the underlying material
For shell & tube heat exchangers, access may be available to individual tubes or to a tube bundle. Depending on the construction and technical condition, high-pressure water cleaning can then be used to remove deposits from inside or around the tubes.
It can also be applied to other industrial heat exchangers where the contaminated surfaces are sufficiently accessible.
Higher pressure does not automatically mean better cleaning
With high-pressure cleaning, the mechanical load must be matched to the design, material and technical condition of the heat exchanger. Higher pressure does not automatically produce a better cleaning result.
The correct combination of pressure, nozzle, stand-off distance and working method should provide enough energy to remove the deposits without unnecessarily loading the heat-transfer surface or other components.
Thin materials, fins, coatings, gaskets and surfaces already affected by corrosion require particular care.
A tube bundle in good technical condition can therefore require a very different cleaning approach from an older exchanger that already shows signs of wall loss or corrosion.
Fouling alone does not determine the cleaning method
Two heat exchangers can both contain mineral scale and still require different cleaning strategies.
That is because contamination is only one variable.
Type of heat exchanger
The design determines how accessible the contaminated surfaces are.
In a demountable plate heat exchanger, individual plates can be separated, inspected and cleaned. A shell & tube heat exchanger presents different access conditions on the tube side, shell side and around the tube bundle.
A charge air cooler has another geometry altogether, with contamination potentially extending deep between the fins.
A method that works well for a plate heat exchanger may therefore be less suitable for an air cooler, even when the type of contamination initially appears similar.
Material
The cleaning method must also match the material underneath the contamination.
This applies to both chemical and mechanical loading.
A stainless-steel plate, titanium plate, aluminium fin or copper-alloy tube has different properties and sensitivities. Gaskets, coatings, brazed joints and other components also need to be taken into account.
Location of the contamination
Not only what is present, but also where it is located influences the cleaning method.
Contamination can be found:
- Inside tubes
- Between plates
- Deep between fins
- Inside narrow channels
- Around inlet or outlet areas
- On waterside surfaces
- On internal surfaces that are difficult to reach mechanically
A hard deposit on a directly accessible surface offers different cleaning options from the same deposit deep inside a narrow passage.
Technical condition
Fouling can also conceal underlying damage.
Under scale, sludge, salt deposits or biofilm, localised corrosion may be present. After cleaning, pitting, material loss, damaged plates or deteriorated tubes may become visible.
Cleaning removes contamination. It does not restore damaged material.
Assessing the technical condition is therefore part of determining the correct maintenance approach.
When are different cleaning methods combined?
In practice, one cleaning method does not always provide the complete solution.
A heat exchanger may first be flushed to remove loose contamination, followed by chemical treatment to remove remaining mineral deposits.
With a tube bundle, mechanical cleaning may be used on accessible, strongly adhered deposits while another treatment is used for contamination in less accessible areas.
The initial cleaning stage can also reveal a second type of deposit or underlying damage that was not visible beforehand.
This is especially relevant with mixed fouling. A combination of sludge, mineral scale, corrosion products and organic contamination may require several cleaning stages rather than one standard process.
The sequence should therefore be determined from what is found during inspection and cleaning.
Inspect first, then select the cleaning method
A change in operating performance is an important signal, but it is not a diagnosis.
A higher pressure drop, for example, can be consistent with fouling or a partial blockage. It can also result from increased flow, changing viscosity, a restricted filter or altered process conditions.
Likewise, a rising outlet temperature does not automatically prove that the heat exchanger needs cleaning.
A good approach therefore starts with collecting and assessing the available information.
At Blue Orange, this assessment can broadly be divided into the following steps:
- Establish the operational complaint or reason for inspection
- Inspect the heat exchanger
- Identify the type and location of contamination
- Assess the material, design and technical condition
- Select an appropriate cleaning method
- Clean the heat exchanger
- Inspect the surfaces again after cleaning
- Perform a pressure or leak test where relevant
- Document the findings, test results and maintenance recommendations
The cleaning method should follow from the diagnosis rather than being selected in advance.
Where available, historical operating and maintenance data can provide additional context. If the pressure drop increases more quickly between successive maintenance intervals, for example, this may indicate a change in the fouling rate or operating conditions.
When is cleaning no longer sufficient?
Cleaning removes contamination. It does not repair damaged material.
During or after cleaning, problems can become visible such as:
- Severe corrosion
- Pitting
- Damaged or deformed plates
- Deteriorated tubes
- Leaks
- Damaged or hardened gaskets
- Cracks
- Structural material loss
At that point, the maintenance question becomes broader than how to clean the heat exchanger.
Repair, component replacement or a complete heat exchanger overhaul may need to be considered.
Rapidly recurring fouling also deserves further investigation. If a heat exchanger becomes heavily fouled shortly after every cleaning, the underlying cause may be outside the exchanger itself.
Possible contributing factors can include water quality, insufficient flow, changing process conditions or changes in the fluid.
Repeated cleaning will remove the deposits, but it will not correct the underlying operating condition.
Which cleaning method does my heat exchanger need?
The choice between chemical, ultrasonic and high-pressure cleaning can be narrowed down by considering seven questions together:
- What type of contamination is present?
Is it scale, sludge, salt, oil, process residue, corrosion products, biofouling or a combination? - Where is the contamination located?
Is it on an accessible surface, inside tubes, between plates or deep between fins? - What material is being cleaned?
And are there gaskets, coatings or other sensitive components to consider? - Can the contamination be reached mechanically?
If not, chemical or ultrasonic cleaning may offer more suitable options. - Can or should the heat exchanger be dismantled?
CIP may avoid disassembly in suitable situations, while inspection or complex contamination may make opening the unit necessary. - What is the technical condition of the heat exchanger?
Are there indications of corrosion, leakage or material loss? - What inspection or testing is required after cleaning?
This may include visual inspection, pressure testing, leak testing or comparison with previous operating data.
Only by considering these factors together can the cleaning method be selected on a technically sound basis.
The most suitable method is therefore not necessarily the most aggressive or powerful method. It is the method that removes the contamination effectively while respecting the design, materials and technical condition of the heat exchanger.
Need or want advice on the right cleaning method?
The most suitable cleaning method ultimately depends on the heat exchanger, the type of contamination and its technical condition.
If it is not immediately clear whether chemical, ultrasonic or high-pressure cleaning is the right approach, Blue Orange can inspect the heat exchanger and assess which cleaning and maintenance method best fits the situation.
Contact us to discuss your heat exchanger and the most appropriate next step.
Sometimes. Chemical Cleaning in Place can be used for suitable heat exchangers by circulating a cleaning solution through the unit. Whether this is possible depends on the design, accessibility of the contamination and whether internal components need to be visually inspected. Heavy or inaccessible contamination can still require disassembly.
It can if the pressure, nozzle, distance or working method are not appropriate for the material and technical condition. Thin, delicate or already deteriorated surfaces require particular care. High-pressure cleaning should therefore be matched to the construction and condition of the unit.
This depends on the heat exchanger and the application. Visual inspection may be part of the assessment, while flow, pressure drop, temperatures and other operating data can provide additional information. When a heat exchanger has been dismantled, plates, tubes and other components can also be assessed individually.
Yes. Mixed or severe fouling may require several cleaning stages. Mechanical treatment can, for example, remove loose or strongly adhered contamination before chemical cleaning is used to address remaining deposits. The appropriate sequence depends on the heat exchanger and the fouling found.
Mineral scale can often be treated chemically, provided that the selected chemistry is compatible with the heat exchanger materials. Thick or mixed deposits may require an additional or alternative mechanical cleaning step.
When a heat exchanger has been opened and reassembled, or when cleaning reveals possible damage, a pressure or leak test may be appropriate. The required checks depend on the type of exchanger, the work performed and the application.