86 heat exchanger tubes replaced under a tight schedule

Cleaning a fresh water generator heater and replacing 86 tubes within a limited maintenance window requires careful coordination between the different stages of the work.

For this project, Blue Orange and Donker Fuel worked together to carry out the cleaning, preparation and tube replacement activities within a tight schedule.

The heater arrived at our workshop in Schiedam on Saturday, where our team handled the cleaning and preparation. By Monday morning, it was ready for transfer to Donker Fuel, where 86 tubes were subsequently replaced.

With two workshops involved, coordinating the work was just as important as the technical activities themselves.

The challenge: previous tube damage and limited maintenance time

The fresh water generator heater already had a documented history of tube damage and earlier repairs.

Technical information supplied by the customer showed that several tubes had previously been plugged or replaced during maintenance operations.

One of the original drawings identified 74 previously replaced tubes, along with additional tubes that had been plugged during subsequent maintenance activities. The accompanying photographs also documented damaged tube surfaces, including changes in surface condition and localised perforation.

When tubes in a heat exchanger develop leaks or damage, several repair options may be considered. One approach is to plug individual tubes, isolating them from the process without immediately replacing the complete tube bundle.

Although tube plugging can be a suitable repair method, it also removes the affected tubes from the available heat transfer surface. As more tubes are taken out of service, the heat exchanger’s thermal capacity may be affected.

The actual impact depends on several factors, including the original design, the number of plugged tubes and the operating conditions.

When damage continues to occur, it becomes important to assess whether further plugging is appropriate or whether replacing the affected tubes offers a better solution.

For this maintenance operation, the required work involved renewing 86 tubes.

The challenge was not limited to the number of tubes. With little time available, the initial inspection, cleaning and preparation had to be completed before the heater could be transferred for mechanical repairs.

Front view of the heater tube sheet, with 86 tubes scheduled for replacement.

Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Inspection and cleaning at the Blue Orange workshop

The heater arrived at the Blue Orange workshop in Schiedam on Saturday.

Before cleaning began, the condition of the unit was documented in a pre-service report. This included photographs of the external surfaces, covers, cooling fins and pipe connections.

External view and connections of a fresh water generator heater at Blue Orange.

A magnetic check was also performed, confirming that the tubes and cooling fins were non-magnetic.

Recording the condition of a heat exchanger upon arrival provides a useful reference for subsequent maintenance activities. This is particularly relevant for equipment with a history of repairs, where it is important to distinguish the existing condition from any findings made during the current maintenance operation.

After the initial inspection, our team carried out the cleaning and preparation work.

Maintenance work on the tube sheet of a marine heat exchanger.

Cleaning an existing heat exchanger requires consideration of its construction, materials and the type of contamination present. Deposits can make it more difficult to assess the condition of components, while contamination around tubes and other surfaces may interfere with subsequent maintenance activities.

Preparing the unit properly is therefore an important part of the overall repair process.

The most suitable cleaning method depends on the specific heat exchanger and the condition in which it arrives. The purpose is not simply to remove contamination, but also to make the relevant areas accessible for further inspection or mechanical work.

For this project, timing was another important consideration. The cleaning had to be completed within the available weekend to allow the heater to be transferred to Donker Fuel for the next stage of the repair.

86 tubes replaced at Donker Fuel

By Monday morning, the heater had been prepared and was ready for transfer to Donker Fuel.

The team at Donker Fuel then took over the mechanical work, replacing a total of 86 tubes.

When carrying out partial retubing of an existing heat exchanger, accurate documentation is particularly important. Not all tubes necessarily have the same maintenance history, and previous repairs may influence which components can be removed or replaced.

In this case, the original customer documentation included several technical details that had to be considered.

For example, specific tubes fitted with spacer pipes were marked on the drawing, together with instructions that these components were not to be removed.

Such details are important when planning tube replacement work. The original configuration of the heat exchanger must be taken into account, including the position of individual tubes and any construction features that need to remain unchanged.

It is also important to distinguish between previously plugged or replaced tubes and those selected for renewal during the current maintenance operation.

The technical drawing supplied by Donker Fuel identifies the 86 newly replaced tubes individually. This provides a clear record of the work carried out and helps distinguish the latest repairs from the heater’s earlier maintenance history.

Coordinating two specialist workshops

When different stages of heat exchanger maintenance take place at separate workshops, the handover between them becomes an important part of the planning.

For this project, the responsibilities were clearly divided.

Blue Orange handled the arrival inspection, cleaning and preparation of the heater. Donker Fuel was responsible for the specialist tube replacement work.

With both workshops located relatively close to each other, transporting the unit between them did not require complicated arrangements. Direct communication between the teams also made it easier to coordinate the timing of the different activities.

This is particularly useful when maintenance must be carried out within a limited timeframe.

Rather than having both companies involved in the same activities, each team could focus on its own area of expertise. Blue Orange prepared the heat exchanger for further maintenance, while Donker Fuel carried out the mechanical work on the tube bundle.

The heater arrived at Blue Orange on Saturday and was already transferred to Donker Fuel by Monday morning, allowing the different stages of the work to follow each other without unnecessary delays.

The result: a cleaned heater and 86 renewed tubes

The heater was received and cleaned at Blue Orange before being transferred to Donker Fuel, where 86 tubes were replaced.

The available technical documentation records both the previous maintenance history and the tubes renewed during this project.

Beyond the actual replacement work, the project required coordination between the different activities. Cleaning, preparation, transport and specialist repairs all had to fit within the available maintenance schedule.

At Blue Orange, we regularly work on the inspection, cleaning, maintenance and overhaul of industrial and marine heat exchangers. Depending on the condition of the equipment, this may involve routine cleaning, more extensive maintenance or additional mechanical repairs.

When specialist tube replacement work is required, we can coordinate these activities with Donker Fuel as part of the maintenance process.

Does your heat exchanger require maintenance, or have damaged tubes been identified? Contact Blue Orange to discuss the condition of your equipment and the available repair options.